IE-2000U-8TC-G Specification
|
| Total Ports |
10 |
| RJ45 Ports |
8 FE |
| Combo Ports |
2 GE |
| IEEE 1588 |
Yes |
| PRP |
Yes |
| Software |
LAN Base |
| Dimensions (H x W x D), Including DIN Rail |
5.1 x 3.6 x 5.26 in (130 x 91.4 x 134 mm) |
| Weight |
3.45 lbs (1.56 kg) |
| Hardware |
● 256 MB DRAM with ECC memory
● 1 GB removable SD flash memory card (CG swap drive) – (128MB space available)
● Mini-USB connector |
| Alarm |
● Alarm I/O: two alarm inputs to detect dry contact open or closed, one alarm output relay. 48 VDC, 0.5A max |
| Power Supply |
● Redundant DC input voltage with operating range: 12-48 VDC Nominal, 9.6-60 VDC Maximum
● Maximum DC input current: 0.5A at 48 VDC, 1A at 24 VDC |
| Power Consumption |
10-port models: 11-16 W |
| Substation Compliance |
● IEC 61850-3
● IEEE1613 |
| Hazardous Location |
● ANSI/ISA 12.12.01 (Class 1, Div 2 A-D) (requires cabinet enclosure)
● UL/CSA 60079-0, -15 (Class 1, Zone 2, group II gases, requires cabinet enclosure)
● EN 60079-0, -15 ATEX certification (Class I, Zone 2, Group II gases, requires cabinet enclosure)
● IEC 60079-0, -15 (Class I Zone 2, Group II gases, requires cabinet enclosure)
● CSA 213 |
| Industrial Control Safety |
● UL508
● CSA C22.2 No. 142 |
| EMC Interface Immunity |
● EN 55024 (CISPR 24)
● AS/NZS CISPR 24
● KN 24
● IEC61000-4-2 (Criteria A – Class 2)
● IEC61000-4-3/ENV50204 (Criteria A)
● IEC61000-4-4 (Criteria A/Criteria B)
● IEC61000-4-5 (Criteria B)
● IEC61000-4-6 (Criteria A) |
| Standard Electromagnetic Emissions Certifications |
● FCC Part 15 Class A
● EN 55022 Class A (CISPR22 Class A)
● ICES-003 Class A
● EN 300 386
● VCCI Class A
● AS/NZS CISPR22 Class A
● CNS 13438 Class A
● KN 22 Class A CE Marking |
| Standard Safety Certifications |
● UL 60950-1
● CSA 60950-1
● EN 60950-1
● IEC 60950-1, CB report and certificate with all national differences |
| Operating Environment |
● Operating Temperature: -40C to +75C
● -40C to +70C (Vented Enclosure – 40 LFM Air Flow)
● -40C to +60C (Sealed Enclosure – 0 LFM Air Flow)
● -34C to +75C (Fan or Blower equipped Enclosure – 200 LFM Air Flow)
● -40 to +85C (IEC 60068-2-2 Environmental Type testing – 100 hours)
● Operating altitude: -60 m (-200 ft) to 3,000 m (10,000 ft), de-rate maximum operating temperature per IEEE 1613-2009:
● Relative humidity: 5% to 95% non-condensing |
| Storage Environment |
● Temperature: -50º C to +85º C
● Altitude: 15,100 ft (4600 m) |
| Warranty |
● Five-year limited warranty on all IE-2000U HW PIDs |
| Mean Time Between Failure (MTBF) |
● 700,760 Hours |
| Protection Class Code |
● IP30 per EN60529 |