N3K-C3064PQ-10GX Specification
|
| Physical |
● 1RU fixed form factor
● Cisco Nexus 3064-X: 64 10 Gigabit Ethernet ports (48 SFP+ and 4 QSFP+)
◦ 48 SFP ports support 1 and 10 Gigabit Ethernet
◦ 4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each
● 2 redundant power supplies
● 1fan tray with redundant fans
● 1 I/O module with management, console, and USB flash memory ports |
| Performance |
● 1.28-Tbps switching capacity
● Forwarding rate of 950 mpps
● Line-rate traffic throughput (both Layer 2 and 3) on all ports
● Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
| Hardware tables and scalability |
MAC addresses |
128,000 |
| Number of VLANS |
4096 |
| Spanning-tree instances |
● Rapid Spanning Tree Protocol (RSTP): 512
● Multiple Spanning Tree (MST) Protocol: 64 |
| ACL entries |
● 2000 ingress
● 1000 egress |
| Routing table |
● 16,000 prefixes and 16,000 host entries
● 8000 multicast routes |
| Number of EtherChannels |
64 (with vPC) |
| Number of ports per EtherChannel |
32 |
| Buffers |
9 MB shared |
| Boot flash memory |
2 GB |
| Power |
Number of power supplies |
2
● Cisco Nexus 3064-X: Redundant for AC and DC power |
| Power supply types |
● AC (forward and reversed airflow)
● DC (forward and reversed airflow) |
| Typical operating power |
● Cisco Nexus 3064-X
◦ 143 watts (W; 64p with Twinax at 100% load; 2 power supply units [PSUs])
◦ 177W (64p with SR optics at 100% load; 2 PSUs) |
| Maximum power |
● Cisco Nexus 3064-X: 199W |
| AC PSUs
● Input voltage
● Frequency
● Efficiency |
● 100 to 240 VAC
● 50 to 60 Hz
● 89 to 91% at 220V |
| DC PSUs
● Input voltage
● Maximum current
● Efficiency |
● -40 to -72 VDC
● 33A
● 85 to 88% |
| Typical heat dissipation |
● Cisco Nexus 3064-X
◦ 488 BTU/hr (64p with Twinax at 100% load; 2 PSUs)
◦ 605 BTU/hr (64p with SR optics at 100% load; 2 PSUs) |
| Maximum heat dissipation |
● Cisco Nexus 3064-X: 683 BTU/hr |
| Cooling |
Forward and reversed airflow schemes:
● Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports)
● Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies)
Single fan tray with redundant fans
Hot swappable (must swap within 1 min) |
| Sound |
Measured sound power (maximum)
● Fan speed: 40% duty cycle
● Fan speed: 60% duty cycle
● Fan speed: 100% duty cycle |
● 59.7 dBA
● 66.4 dBA
● 71.0 dBA |
| Environment |
Dimensions (height x width x depth) |
● Cisco Nexus 3064-X: 1.72 x 17.3 x 19.7 in. (4.4 x 43.9 x 50.5 cm) |
| Weight |
● Cisco Nexus 3064-X: 20.5 lb (9.3 kg) |
| Operating temperature |
32 to 104°F (0 to 40°C) |
| Storage temperature |
-40 to 158°F (-40 to 70°C) |
| Operating relative humidity |
● 10 to 85% noncondensing
● Up to 5 days at maximum (85%) humidity
● Recommend ASHRAE data center environment |
| Storage relative humidity |
5 to 95% noncondensing |
| Altitude |
0 to 10,000 ft (0 to 3000m) |
Reviews